- 관련 Fluke 회사:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Wide selection, with the best digital temperature control available
- Stability to ±0.0007 °C
- Best digital temperature controller available
- “Super Tweak” function provides set-point resolution to 0.00003 °C
- Excellent for maintaining fixed-point cells
Find a refrigerated calibration bath for low temperatures (i.e. –40 °C). Fluke Calibration metrology baths are well known world-wide for excellent temperature control that maintains excellent temperature stability (±0.0015 °C) and uniformity (±0.003 °C). Model 7040 can be used with Fluke Calibration bath fluids to safely reach high and low temperatures.
Fluke Calibration’s temperature calibration baths are known around the world as the best calibration baths made. If you’re looking for a cold bath, no one gives you more choices than Fluke Calibration.
This bath operates at temperatures as low as –40 °C, and is built using CFC-free refrigerants. Fluke Calibration’s proprietary controller design and unique tank construction produce bath stabilities to ±0.001 °C or better. These baths are so stable and uniform that national labs use them for comparison calibrations and fixed-point cell maintenance.
The bath is fully automatable with a bath interface package and Fluke Calibration’s MET/TEMP II automation software package. When we automate a bath, we automate it completely with computer-controlled solenoid valves for precision balancing of the heating and cooling system. MET/TEMP II performs all calibration tasks automatically, using your PC.
With a Fluke Calibration cold bath, you can forget external coolants. Internal refrigeration systems are all that’s needed to reach each bath’s coldest temperature. Most cold baths may be ordered with an optional pumping lid for supplying external cooling requirements.
Specifications | |
Model |
7040
|
Range |
–40 °C to 110 °C
|
Stability |
±0.002 °C at –40 °C (ethanol)
±0.0015 °C at 25 °C (water) ±0.003 °C at 100 °C (oil 5012) |
Uniformity |
±0.004 °C at –40 °C (ethanol)
±0.002 °C at 25 °C (water) ±0.004 °C at 100 °C (oil 5012) |
Temperature Setting |
Digital display with push-button data entry
|
Set-Point Resolution |
0.01 °C; high-resolution mode, 0.00007 °C
|
Display Resolution |
0.01 °C
|
Digital Setting Accuracy |
±1 °C
|
Digital Setting Repeatability |
±0.01 °C
|
Heaters |
500 and 1000 Watts
|
Access Opening (call for customs) |
127 x 254 mm(5 x 10 in)
|
Depth |
305 mm (12 in)
|
Wetted Parts |
304 Stainless Steel
|
Power |
115 VAC (±10 %), 60 Hz, 16 A or 230 VAC (±10 %), 50 or 60 Hz, 9 A (specify voltage and frequency)
|
Volume |
27 liters (7.2 gal)
|
Weight |
63.5 kg (40 lb)
|
Size |
622 x 768 x 483 mm (24.5 x 30.25 x 19 in)
|
Automation | Use the 1586A Super-DAQ to automate temperature sensor calibration |
Model Name | 설명 |
---|---|
7040 |
표준 Bath, –40 °C ~ 110 °C |
Accessories common to all models:
액세서리 | 설명 |
---|---|
항온조 매질 | |
2069 |
설치부 포함 8배율 확대경 |
2033 |
IR 원추(NIST 설계) |
2071 |
Bath 카트, 7011, 7012 (312 mm [12.3 in] 높이) |
2073 |
Bath 카트, , 7008, 7037, 7040 (216 mm [8.5 in] 높이) |
2011 |
접근덮개, 184 x 324 mm (7.25 x 12.75 in),렉산(7008) |
2010-5 |
접근덮개, 162 x 292 mm (6.38 x 29.21 cm),렉산(7037) |
2027-5901 |
TPW 고정대(7012,7037) |
2611 |
서미스터 프로브 |
2620 |
RTD 프로브, 280 mm (11 in.) |
2624 |
RTD 프로브, 355 mm (14 in.) |
- 홈
- 제품
- 구입처 안내
- 뉴스
- 교육 및 세미나
- 사용자 가이드
- 서비스 및 지원
- 회사 정보
Sidebar Request a Quote
견적 요청