- 관련 Fluke 회사:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
GFSTools PC Based Software
TITLE | VER | USE WITH | |
GFSTools™ | 1.01 2010.12.03 |
GFS 2102 | |
Description | |||
GFS Tools is a PC based application used to operate the GFS 2102 Gravimetric Flow Standard. | |||
Summary | |||
GFS Tools is the PC based interface to the GFS 2102. All necessary features are included to log data for up to 2 DUTs in comparison to the GFS from 1 sccm of N2 to 10 slm of N2. Options are provided to set manual or automatic flows using an MFC and to define a test sequence of flow points to fully automate a calibration. GFS Tools also provides maintenance functions required to ensure consistent functionality of the GFS 2102.
GFS Tools is specifically designed to operate a GFS 2102. This program cannot be used without complete GFS 2102 hardware. |
|||
Instructions: | |||
Download and run the file. The installation program will prompt you through the process. | |||
Updates Include: | |||
Rev 1.01 (2010.12.03) CHG(GFS-11):The About dialog now uses the new FLUKE Calibration logo. CHG(GFS-10):The splash screen was updated to use the new FLUKE Calibration logo. CHG(GFS-9):The [Setup][Configuration]‹System› tab options are all limited to acceptable values. CHG(GFS-7):The balance weighing settings are changed to standard mode to increase the success rate of internal calibrations. The settings used during normal GFS operation are unnecessarily restrictive. FIX(GFS-8):The GFS dew point calculation incorrectly used the ambient temperature and humidity. The calculation is now based on TH Probe#2 which is located near the gas cylinder. FIX(GFS-4):Resolved an "Overflow Error" that could occur when testing a low flow accumulation when using a Min Mass per GFS sample that was relatively large compared to the flow rate. FIX(GFS-3):A flow stability test is no longer applied to the last accumulation of a test point when a flow pause per accumulation is used. The stability test was waisted as it achieved stability at the current test point even though a new test point was sent immediately following stability test. FIX(GFS-2):Resolved Runtime Error 91 that could occur when accessing the [Tools][PC Timer Calibration] menu prior to running an accumulation. FIX(GFS-1):The [Setup][Configuration] menu choice did not save the Time Tolerance limits between executions of GFS Tools. Rev 1.00h (2009.09.29) Rev 1.00g (2009.04.24) Rev 1.00f (2007.11.29) Rev 1.00e (2007.03.08) Rev 1.00d (2006.11.16) |
- 홈
- 제품
- 구입처 안내
- 뉴스
- 교육 및 세미나
- 사용자 가이드
- 서비스 및 지원
- 회사 정보